Williamson-Thermoflo PMP/PLB-098 (98 MBH)

Manufacturer:    Williamson-Thermoflo
Appliance Series:    PMP/PLB
Appliance Model:    PMP/PLB-098
Burner Model:    EZGas Pro
Difusser:    9S
Air Tube:    10"
OEM Air Tube #:    Universal
Insertion Depth:    1 3/4
Input MBH:   98
Natural Gas Orifice:    7/32 (.219)
Propane Orifice:    #20 (.161)
Air Setting:   28%
Air Band:   1 slot
Head Bar:   -
Air Shutter:    blank
Manifold Pressure:    3.2NG/ 3.6LP