CHOOSE A DIFFERENT MANUFACTURER 6


CHOOSE A DIFFERENT APPLIANCE

Burnham (U.S. Boiler) V15

ALL BLENDS (#2-B100) SETTINGS

Manufacturer:    Burnham (U.S. Boiler)
Appliance Series:    V1
Appliance Model:    V15
Burner Model:    EZ-1
Air Tube:    5" EZ-1
OEM Air Tube #:    84822
Insertion Depth:    1.75
Nozzle GPH:   1.10
Nozzle Type:    60A
Nozzle Mfr:    Delavan
Alternative Nozzle Type:   
Alternative Nozzle Mfr:   
Pump PSI:   150
Air Shutter:    EZ-1
Head Position:    [GPH 1.35/1.50] or (Position 5)
Air Setting:    [1.35 GPH] or (75% Open)
NOTES:   


B100 Field Conversion Guide

Use the below steps to convert a burner mfg before 11/20/2023 for optimization with all blends.

  1. Change Combustion Head Assembly* – Use Part No 77958S
    * Make sure combustion head has a gold C-clip (which designates that it is our B100 design.)
  2. Check/Replace Pump – Install Suntec Pump #3006B rated for B100
  3. Make changes highlighted in green above
  4. Check/Replace Control – Install ProX 70200 if the burner does not already have one.
  5. Check/Change Settings on ProX 70200**:
    • Flame stabilization:  5 seconds
    • CAD Ohms Max: 5300
    • Ignition Type: Smart Ignition
    • Motor Delay Off (Post-Purge): Minimum 15 seconds


** ProX 70200 controls manufactured after 11/20/23 will already have these settings.
Go to Top